Designation and options:
Volume flow rate measuring of pressure control system waste water with telemetric data display.
Modifications with interface RS-485 or current output 4-20mA are also possible. Modification of the flow meter with LCD indicator allows to control instant and cumulative flow rate on the front panel of the device.
Principle of action:
Measuring of the electromotive force induced by geomagnetic field in the conducting fluid proportional to the average speed of the flow. Volume flow rate that goes through the pipelinetransforms intomultiple electric pulses with data grade circuit (0.001 m3, 0.01m3, 0.1m3, 1 m3), this format can be modified on the Customer’s request.
Characteristics:
Modifications:
Technical Characteristics | |||||
Maximum operating pressure, MPa (psi) | 21 (3000) | ||||
Name of the product | KR2-32A | KR2-32 | KR2-65 | KR2-100 | |
Nominal bore (Dy), mm | 32 | 32 | 65 | 100 | |
Ring gasket diameter for flange connection (Dn), mm | 80 | 128 | |||
Flow rate range, m3/per hour | 0.3…30 | 0.3…30 | 1.3…130 | 3…300 | |
Operational temperature ranges, °C | -50…+50 | ||||
Operational temperature ranges with LCD indicator, °C | -40…+50 | ||||
Relative error, not to exceed % | +-1.5% | ||||
Electricity supply, V | 24+-5 | ||||
Required power, W | 5 | ||||
Dimensions, (DxLxH), mm. | 110x140x320 | 160x160x370 | 160x160x370 | 180x160x390 | |
Weight, (not exceeding) kg | 7.9 | 12.3 | 11.2 | 13.9 |