It is intended for hanging of production and technical casings at all stages of well construction and operation, sealing and separation of annular space, pressure control in annular space, installation of blowout equipment on the top and intermediate flanges.
Climatic category of the wellhead equipment — UHL(HL1) in accordance with the national standard GOST
Temperature ranges +40°C −60°C.
Product specification level UTT2 in accordance with the national standard GOST R
Technical Characteristics | |||||
Product Name | OKp1 | OKp1K | OKp2K | OKp2K | |
Maximum operating pressure, MPa (psi), not to exceed | 14(2000)/21(3000)/35(5000) | ||||
Type of the Casing Hanger | Threaded | Slip-type | |||
Diameter | Surface Casing | 245 | 219, 245 | 299, 324 | 426 |
Technical Casing | - | - | 219, 245 | 245, 324 | |
Production Casing | 140, 146, 168, 178 | ||||
Flowing fluid temperature, not to exceed | 120 |